13
1.7. Sweep Wave Command
DESCRIPTION Set or get sweep wave parameters.
COMMAND SYNTAX <channel>:SWeepWaVe <parameter>
<channel>:={C1, C2}
<parameter>:= {a parameter from the table below. }
Parameters
Value
Description
STATE
<state>
Turn on or off sweep
wave. Note if you want to
set or read sweep wave
parameters, you must
first enable sweep mode.
TIME
<time>
Value of sweep time
STOP
<stop frequency>
Value of stop frequency
START
<start frequency>
Value of start frequency
TRSR
<trigger src>
Trigger source
TRMD
<trigger mode>
Value of trigger output. If
TRSR is EXT, the
parameter is invalid.
SWMD
<sweep mode >
Sweep way
DIR
<direction>
Sweep direction
EDGE
<edge>
Value of edge. Only TRSR
is EXT, the parameter is
valid.
MTRIG
<manual trigger>
Make the device once
manual trigger. The
parameter is valid only
when TRSR is set to MAN.
CARR,WVTP
<wave type>
Value of carrier wave type.
CARR,FRQ
<frequency>
Value of frequency.
CARR,AMP
<amplifier>
Value of amplifier.
CARR,OFST
<offset>
Value of offset.
CARR,SYM
<symmetry>
Value of symmetry.
CARR,DUTY
<duty>
Value of duty cycle.
Only Square can set this
parameter.
CARR,PHSE
<phase>
Value of phase.
Note: If Carrier wave is Pulse or Noise, enabling sweep is not allowed.