Página 3

PULL INVert:When pushed in, the polarity of the channel 2 signalis normal. When pulled out, the polarity of thechannel 2 signal is reversed, thus

Página 4 - TABLE OF CONTENTS

TRIGGERING CONTROLS30. HOLDOFF/PULL CHOP Control.HOLDOFF:Rotation adjusts holdoff time (trigger inhibit periodbeyond sweep duration). When control is

Página 5

OPERATING INSTRUCTIONSNOTEAll operating instructions in this chapterapply equally to all Models except for thesections on “Delayed Sweep Operation&quo

Página 6 - OTHER FEATURES

OPERATINGTIPSThe following recommendations will help obtain the bestperformance from the oscilloscope.1. Always use the probe ground clips for best re

Página 7

3. To view both waveforms simultaneously, set theVERTical MODE switch to DUAL and select eitherALT (alternate) or CHOP with the PULL CHOPswitch.4. In

Página 8 - ACCESORIES SUPPLIED:

Trigger SOURCE SwitchThe trigger SOURCE switch (CH 1, CH 2, etc.) selectsthe signal to be used as the sync trigger.1. If the SOURCE switch is set to C

Página 9

This control is usually set to the MIN position (fullycounterclockwise) because no additional holdoff period isnecessary. The HOLDOFF control is usefu

Página 10

and clockwise rotation causes more of the display tobe occupied by the delayed sweep.4. Set the Sweep Mode switch to the DELAY positionto display only

Página 11 - HORIZONTAL CONTROLS

OPERATING INSTRUCTIONSFig. 6. Typical Resistive Signatures.17

Página 12 - TRIGGERING CONTROLS

TEST INSTRUMENT SAFETYWARNINGNormal use of test equipment exposes you to a certain amount of danger from electrical shock becausetesting must often be

Página 13 - OPERATING INSTRUCTIONS

InductorsLike capacitance, a purely inductive impedance producesa signature that is an ellipse or circle and value is determinedby the size and shape

Página 14 - DUAL TRACE DISPLAY

SemiconductorsPurely semiconductor devices (such as diodes and transis-tors) will produce signatures with straight lines and bends.Typical diode junct

Página 15 - TRIGGERING

MAINTENANCEWARNINGThe following instructions are for use byqualifiedservice personnel only.To avoidelectricalshock, do notperform any serv-icing other

Página 16 - A. Holdoff not used

CALIBRATION CHECKA general check of calibration accuracy may be made bydisplaying the output of the CAL terminal on the screen.This terminal provides

Página 17 - APPLICATIONS GUIDEBOOK

APPENDIXIMPORTANT CONSIDERATIONS FOR RISE TIMEAND FALL TIME MEASUREMENTSError in Observed MeasurementThe observed rise time (or fall time) as seen on

Página 19

DISPLASY RESOLUTION: Auto select from 0.001Hz to 1KHz depending on the frequency. MAX COUNTER RANGE: 0.1Hz to 50MHZ MAXIMUM EXTERNAL VOLTAGE 300

Página 22 - MAINTENANCE

INFORMATIONOne of the best tutorials on oscilloscopes in the industry. Valuable to those with little knowledgeof oscilloscopes as well as the experien

Página 24 - APPENDIX

22820 Savi Ranch Parkway, Yorba Linda, CA 92887 ©2013 B+K Precision Corp. 481-312-9-002C

Página 25

TABLE OF CONTENTSPage PageTEST INSTRUMENT SAFETY . . . . . . inside front coverFEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 27

AUTO SweepSelectable AUTO sweep provides sweep without trig-ger input, automatically reverts to triggered sweepoperation when adequate trigger is appl

Página 29 - INFORMATION

Trigger Coupling:AUTO: Sweep free-runs in absence ofsuitable trigger signal.NORM: Sweep triggered only by adequatetrigger signal.TV-V: Video vertical