40,000 Count Dual-Display Handheld LCR Meters
878B and 879B
Features & Benefits
Data Sheet
www.bk prec ision.c om
Technical data subject to change
© B&K Precision Corp. 2013
B&K Precision’s 878B and 879B 40,000-count
handheld LCR meters measure inductance,
capacitance, and resistance quickly and precisely.
Additionally, the 879B can calculate impedance,
Theta, and ESR, features typically found in bench
LCR meters only.
Fast auto ranging and quick measurement config-
uration such as measurement parameter and test
frequency selection make the 878B and 879B
very simple to operate. The meters also include
handy functions such as data hold,
Min/Max/Average recording, tolerance sorting,
and relative mode.
Measurement data can continuously transfer to a
PC via the meter’s mini USB interface, using
either the provided data logging software or
SCPI commands sent from a custom program.
4
0,000 counts resolution on primary and
10,000 counts resolution on secondary display
L, C, R and Z (879B only) primary
measurements
Automatic calculation of secondary parameters
D, Q, θ, ESR (θ/ESR for 879B only)
0.5% basic accuracy
Fast auto range design for rapid, easy
component measurements
Relative mode
Visible and audible tolerance mode
Data Hold and Min/Max/Average recording
USB (Virtual COM) interface
SCPI compliant commands for remote
communication
Software for datalogging and front panel
emulation available as free download
Selectable auto-power-off options
Configurable power-up-states
3 year warranty
Applications
Passive component trouble shooting
Electronic assembly
Quality control (component sorting)
Full Featured Handheld LCR Meters
Model 879B has the ability to measure the ESR
(Equivalent Series Resistance) of capacitors. ESR
is the sum of in-phase AC resistance of a capaci-
tor and used to rate a capacitor’s quality. An
ideal capacitor would be lossless and have an
ESR of zero. A capacitor could measure the cor-
rect capacitance value, yet still be defective, due
to the component’s excessive in-phase AC resist-
ance. The 879B would be able to detect this
faulty component.
ESR Measurements
Specifi cati ons 87 8B 87 9B
Measurements L, C, R, D, Q
L, C, R, Z, D, Q, θ, ESR
Test frequency 120 Hz, 1 kHz
100Hz, 120 Hz,
1 kHz, 10 kHz
Backlit display No yes
Tolerance mode 1%, 5%, 10% 1%, 5%, 10%, 20%
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - Data Sheet

40,000 Count Dual-Display Handheld LCR Meters878B and 879BFeatures & BenefitsData Sheetwww.bk prec ision.c omTechnical data subject to change© B&a

Página 2 - Easy Front Panel Operation

2 ww w.bk prec ision.c omDual-Display Handheld LCR Meters Models 878B and 879BVersatile Configuration ▲Easy Front Panel Operation▲LCD protective visor

Página 3 - Specifications

3 ww w.bk prec ision.c omDual-Display Handheld LCR Meters Models 878B and 879BAccuracy SpecificationsSpecificationsModel 878B 879B Measurement Paramet

Página 4 - Specifications (cont.)

4 ww w.bk prec ision.c omDual-Display Handheld LCR Meters Models 878B and 879BSpecifications (cont.)Ra nge Ma x Display Cx Acc uracyDF(Dx <0.5)Me