20
TTL
CMOS
USER
HIPRED | LOPRED
o OUTPUT LIMITS
LIM OF
LIM ON
HILIM
LOLIM
PREV
- PULSE
o RISE
o FALL
o EQUAL
o NORM | COMPL
- MODE
o CONT
o TRIG
MAN (Manual Trigger)
INT (Internal Trigger Rate)
EXT (External Trigger)
PREV
o GATE
MAN (Manual Gate Trigger)
INT (Internal Gate Trigger Rate)
EXT (External Gate Trigger)
PREV
o BURST
MAN (Manual Burst)
INT (Internal Burst Rate)
EXT (Burst External)
NBRST (Number of Bursts)
PREV
o EXTWID
- SETUPS
o RECALL
o STORE
o CLEAR ALL
- UTIL
o GPIB (ACTIVE) (GPIB Address)
o RS232 (ACTIVE) (Baudrate)
o INTEN
o POWER (Power On Setup)
3.6.1 PARAMETER Menu
This key selects and displays the waveform frequency, amplitude, offset and external reference and allows changing the
parameter data.
Frequency Menu
F1: PERIOD/FREQ - Selects and displays the period or the pulse frequency. Change the values using the
cursor keys, rotary knob or numerical keys. If a certain setting can't produce the
waveform at the desired parameters, the generator displays an error message. While the